PAROC Hvac Section AluCoat T is a concentric, dimensionally accurate rockwool pipe wrap laminated with a mesh-reinforced aluminum foil, self-adhesive overlap, slotted on one side.
Since 30.06.2022, further insulation with the Paroc shell can be carried out without any problems after bulkheading with a shell from most other bulkhead manufacturers; the new test certificate P-3124.165.14-MPA BS makes this possible. Subsequent further insulation with the other manufacturer's products is no longer necessary according to this test certificate.
It is important to note that all penetration seals produced in accordance with Paroc test certificate P-3124.165.14-MPA BS must be marked with the Paroc identification plate.
-
Acoustic insulation
-
High temperature insulation
-
Passive fire protection
-
Thermal insulation
-
Accessories
Product code | Product omschrijving | Diameter | Dikte | Lengte | ||
---|---|---|---|---|---|---|
View variation | 1015.219090.01-00 | Paroc HVAC Section AluCoat T - Ø219 - 90 mm (1,2m/stk) | 219 mm | 90 mm | 1200 mm | |
View variation | 1015.219100.01-00 | Paroc HVAC Section AluCoat T - Ø219 - 100 mm (1,2m/stk) | 219 mm | 100 mm | 1200 mm | |
View variation | 1015.273030.01-00 | Paroc HVAC Section AluCoat T - Ø273 - 30 mm (1,2m/stk) | 273 mm | 30 mm | 1200 mm | |
View variation | 1015.273040.01-00 | Paroc HVAC Section AluCoat T - Ø273 - 40 mm (1,2m/stk) | 273 mm | 40 mm | 1200 mm | |
View variation | 1015.273050.01-00 | Paroc HVAC Section AluCoat T - Ø273 - 50 mm (1,2m/stk) | 273 mm | 50 mm | 1200 mm | |
View variation | 1015.273060.01-00 | Paroc HVAC Section AluCoat T - Ø273 - 60 mm (1,2m/stk) | 273 mm | 60 mm | 1200 mm | |
View variation | 1015.273070.01-00 | Paroc HVAC Section AluCoat T - Ø273 - 70 mm (1,2m/stk) | 273 mm | 70 mm | 1200 mm | |
View variation | 1015.273080.01-00 | Paroc HVAC Section AluCoat T - Ø273 - 80 mm (1,2m/stk) | 273 mm | 80 mm | 1200 mm | |
View variation | 1015.273090.01-00 | Paroc HVAC Section AluCoat T - Ø273 - 90 mm (1,2m/stk) | 273 mm | 90 mm | 1200 mm | |
View variation | 1015.273100.01-00 | Paroc HVAC Section AluCoat T - Ø273 - 100 mm (1,2m/stk) | 273 mm | 1200 mm | ||
View variation | 1015.305050.01-00 | Paroc HVAC Section AluCoat T - Ø305 - 50 mm (1,2m/stk) | 305 mm | 50 mm | 1200 mm | |
View variation | 1015.305060.01-00 | Paroc HVAC Section AluCoat T - Ø305 - 60 mm (1,2m/stk) | 305 mm | 60 mm | 1200 mm | |
View variation | 1015.305070.01-00 | Paroc HVAC Section AluCoat T - Ø305 - 70 mm (1,2m/stk) | 305 mm | 70 mm | 1200 mm | |
View variation | 1015.305080.01-00 | Paroc HVAC Section AluCoat T - Ø305 - 80 mm (1,2m/stk) | 305 mm | 80 mm | 1200 mm | |
View variation | 1015.305100.01-00 | Paroc HVAC Section AluCoat T - Ø305 - 100 mm (1,2m/stk) | 305 mm | 100 mm | 1200 mm | |
View variation | 1015.324050.01-00 | Paroc HVAC Section AluCoat T - Ø324 - 50 mm (1,2m/stk) | 324 mm | 50 mm | 1200 mm | |
View variation | 1015.324060.01-00 | Paroc HVAC Section AluCoat T - Ø324 - 60 mm (1,2m/stk) | 324 mm | 60 mm | 1200 mm | |
View variation | 1015.324070.01-00 | Paroc HVAC Section AluCoat T - Ø324 - 70 mm (1,2m/stk) | 324 mm | 70 mm | 1200 mm | |
View variation | 1015.324080.01-00 | Paroc HVAC Section AluCoat T - Ø324 - 80 mm (1,2m/stk) | 324 mm | 1200 mm | ||
View variation | 1015.324090.01-00 | Paroc HVAC Section AluCoat T - Ø324 - 90 mm (1,2m/stk) | 324 mm | 90 mm | 1200 mm |
Type examination certificate (module B) No. VTT-C-12177-15-17 issued by VTT.
The temperature on the aluminum side should not exceed 80°C. (This is because of the glue we use to bond the aluminum).
PAROC rock wool products are resistant to high temperatures. The binder evaporates when heated above 200°C. Insulation properties will remain unchanged, but compressibility will be reduced. The melting point of rock wool is above 1000°C.
Fire protection classification, Euroclass A2L - s1, d0 EN 14303:2009+A1:2013 (EN 13501-1)
Fire protection classification/application Pipe partitions for non-combustible pipes of fire resistance classes R-30 to R 90 (AbP Nr. P-3124/165/14-MPA BS). Pipe partitions for flammable pipes of the fire-resistance classes R-30 to R 120 (AbP Nr. P-3126/167/14-MPA BS). Viega Rohrleitungssystem-Abschottung' pipe partitions of fire resistance classes R-30 to R-90 (AbP Nr. P-2400/003/15-MPA BS) DIN 4102-11
Fire classification (IMO) Non-combustible IMO FTP Code Part 1
Fire Classification, Surface (IMO) Surface Flammability IMO FTP Code Part 5
Non-combustibility Non-combustible EN ISO 1182
Thermal insulation properties :
Thermal conductivity at 10 °C, λ 10 0.033 W/mK EN 14303:2009+A1:2013 (EN ISO 8497)
Thermal conductivity at 50 °C, λ 50 0.037 W/mK EN 14303:2009+A1:2013 (EN ISO 8497)
Thermal conductivity at 100 °C, λ100 0.044 W/mK EN 14303:2009+A1:2013 (EN ISO 8497)
Thermal conductivity at 150 °C, λ150 0.053 W/mK EN 14303:2009+A1:2013 (EN ISO 8497)
Thermal conductivity at 200 °C, λ200 0.064 W/mK EN 14303:2009+A1:2013 (EN ISO 8497)
Thermal conductivity at 250 °C, λ250 0.077 W/mK EN 14303:2009+A1:2013 (EN ISO 8497)
Dimensions and tolerances T8 for outer diameter < 150 mm, T9 for outer diameter ≥ 150 mm EN 14303:2009+A1:2013
Thermal conductivity at 40 °C, λ40 0.035 GEG
Short-term water absorption WS, Wp ≤ 1 kg/m² EN 14303:2009+A1:2013 (EN 13472)
Water vapor diffusion resistance MV2 EN 14303:2009+A1:2013 (EN 13469)
Chloride ions, Cl- < 10 ppm EN 14303:2009+A1:2013 (EN 13468)
Thermal and condensation insulation of pipework and air ducts